4 odu | utilities, 1 odu | utilities (csat-5060) – Comtech EF Data CDM-625A User Manual

Page 518

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

CDM-625A ODU (Transceiver, BUC, LNB) Operation

Revision 3

10–50

10.4.2.4.4 ODU | Utilities

The appearance of the ‘ODU | Utilities’ page adjusts to the type of ODU that is

configured for operation with the CDM-625A.

Use this page to configure various ODU utility functions for either the Comtech EF Data

CSAT-5060 or the KST-2000A/B ODU.

10.4.2.4.4.1 ODU | Utilities (CSAT-5060)

Figure 10-13 shows the ‘ODU | Utilities page as it appears when you configure the Comtech EF

Data CSAT-5060 as the ODU.

Figure 10-13. ODU | Utilities page (CSAT-5060)

ODU Selection

If you use ODUs in redundancy, you may toggle this page between the Online and Offline units.

Use the drop-down list to select CSAT #1 or CSAT #2, and then click [Select ODU]. A message

identifies the currently active unit as ‘ONLINE’ in the right-hand column of this section.

Force 1:1 Switch

If you use ODUs in redundancy, and the selected unit is currently the Online unit, click [Force 1:1

Switch] to force a switchover so the unit will then be in Offline (standby) mode. The command is

only valid for the Online unit in a 1:1 pair.

Advertising