Comtech EF Data CDM-625A User Manual

Page 356

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–44

Parameter

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

…Global

Configuration

(cont.)

BBBCCC=CnC search delays

D=CnC PMSI mode

ee=Compressed Ethernet port speed

E=Attach summary BUC alarm to Tx

F=Attach summary LNB alarm to Rx

GG=WAN buffer length

H=Dedicated Management Port

same as CSD

same as CPM

see ** Note

same as ABA

same as ALA

same as WBL

same as DMP

Note: Much of the CDM-625A MGC format carries over from the 600/L MGC format, except where “*” indicates the

differences. For “**ee=Compressed Ethernet port speed” Ethernet port speed is compressed from 4 bytes in SEC

command to 2 bytes in MGC. The first byte represents speed settings for Ports 1 and ; the second byte represents speed

settings for Ports 3 and 4. In each byte, character A through Y is used to represent 25 possible combinations of two port

speed. A=00, B=01, C=02, D=03, E=04, F=10, G=11, H=12, I=13, J=14, K=20, L=21, M=22, N=23, O=24, P=30, Q=31,

R=32, S=33, T=34, U=40, V=41, W=42, X=43, Y=44.

Example: BN is converted to 0123, that means Port 1 is AutoNeg, Port 2 is 100Full, Port 3 is 100Half, Port 4 is 10Full.

OGC Outdoor Unit

Global Copy

OGC=

50 Bytes

Command or Query.

ODU Global Configuration of CDM-625A, in the form shown in the Response to Query column (to the right), where:

OGC=

OGC?

OGC*

OGC#

OGC?

OGC?n (where n=0

thru 9. Returns the

OGC portion of 1 of

10 stored

configurations)

OGC=aabxdexxxxxggg

ghhhhxxxxixklllnnnFFF

FFSfffffsxxxxxx

(Returns current OGC

Configuration)

aa=BUC Address

b=BUC Tx Output Enable

x (spare)*

d=BUC Power Supply

e=BUC 10MHz Reference State

xxxxx (spares)

gggg=BUC Current - Low Limit

hhhh=BUC Current - High Limit

xxxx (spares)*

i=LNB Power Supply*

x (spare)*

k=LNB 10MHz Reference

lll=LNB Low Alarm Limit

nnn=LNB High Alarm Limit

FFFFFS=TX LO Frequency

fffffs=RX LO Frequency

xxxxxx (spares)

same as BAD

same as BOE

same as BPS

same as BFR

same as BCL

same as BCH

same as LPS

same as LNR

same as LNL

same as LNH

same as TLO

same as RLO

Notes:

1) Much of the CDM-625A OGC format carries over from the CDM-600L OGC format, except where “*” indicates the

differences. In 600L Emulation Mode, the OGC format follows the CDM-600L OGC format.

2) Any unavailable parameters will be filled with x’s.