9 lnb parameters (l-band device) – Comtech EF Data CDM-625A User Manual
Page 372

CDM-625A Advanced Satellite Modem
MN-CDM625A
Serial-based Remote Product Management
Revision 3
8–60
8.5.9
LNB Parameters (L-Band Device)
Parameter
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
LNB
DC Power
Control
LPS=
Exception –
600L Emulation:
LNB & LNV
1 byte, 0 thru 3 Command or Query.
Sets or returns LNB DC Power Supply Control in the form x, where:
0=OFF
1=13V LNB Voltage
2=18V LNB Voltage
3=24V LNB Voltage
LPS=
LPS?
LPS*
LPS#
LPS?
Exception –
600L Emulation:
LNB & LNV
LPS=x
(see Description of
Arguments)
LNB
Reference
Enable
LNR=
1 byte, 0 or 1
Command or Query.
Sets or returns LNB Reference in the form x, where:
0=Disable LNB Reference
1=Enable LNB Reference
LNR=
LNR?
LNR*
LNR#
LNR?
LNR=x
(see Description of
Arguments)
LNB
Low Current
Limit
LNL=
3 bytes,
numeric
Command or Query.
Sets or returns LNB Low Current Limit in the form xxx, where:
xxx=Value, in mA, from 000 thru 500.
LNL=
LNL?
LNL*
LNL#
LNL?
LNL=xxx
(see Description of
Arguments)
LNB
High Current
Limit
LNH=
3 bytes,
numeric
Command or Query.
Sets or returns LNB High Current Limit in the form xxx, where:
xxx= Value, in mA, from 000 thru 500
LNH=
LNH?
LNH*
LNH#
LNH?
LNH=xxx
(see Description of
Arguments)
LNB
Current
N/A
4 bytes,
numeric
Query only.
Returns LNB Current in the form xxxx, where:
xxxx=Value, in mA.
N/A
LNC?
LNC=xxxx
(see Description of
Arguments)
LNB
Voltage
N/A
4 bytes,
numeric
Query only.
Returns LNB Voltage in the form xxxx, where:
xxxx=Value, in volts.
N/A
LVO?
LVO=xxxx
(see Description of
Arguments)