CDM-625A Advanced Satellite Modem

MN-CDM625A

Front Panel Operation

Revision 3

6–16

Lower Limit

Upper Limit

Step size (Increment)

0.0 dB

6.0 dB

0.1 dB

CONFIG: Tx Power Mode AUPC Alarm-Action (IP-ACM or

V2-ACM Mode)

Tx-Alarm: Max Power (MaxPwr,MinMCod,None)

Rem Demod Unlock Act=NomPwr(Nom,Max,Hold)

On the top line – Use the

▲▼ arrow keys to select the alarm action that occurs if the AUPC

causes the maximum output power level to be reached. Valid settings are:

Setting

Alarm Function

MaxPwr

(Maximum Power) Generates alarm when maximum power is reached.

MinMCod

(Minimum ModCod) Generates alarm if minimum ModCod is reached.

None

Generates no alarm.

On the bottom line

Use the

▲▼ arrow keys to select the action that occurs if the remote

demodulator is unlocked. Use the

▲▼ arrow keys to select a parameter. Valid settings are:

Setting

Function

Nom

(Nominal Power) The output level reverts to the nominal power level set under Manual.

Max

(Maximum Power)The output level changes to the permitted maximum.

Hold

The output level is maintained at the value just before the remote demod lost lock.

CONFIG: Tx Power Mode CnC-APC Mode

Appendix F. Double Talk Carrier-in-Carrier Option

When you select CnC Automatic Power Control (CnC-APC) mode, this menu appears as shown:

Output Power Mode = CnC-Auto-Power-Control

Level=-25.0dBm MaxPwrIncrease=2.5dB ()

On the bottom line – Edit the power output level and the maximum permitted increase in

power level when in APC Mode. Use the

◄ ►

arrow keys to select a digit, and then use the

▲▼

arrow keys to change that digit. Press ENTER.

Note that, when APC is in an active state, the power level values display in the bottom left as

‘AUTO’.