Comtech EF Data CDM-625A User Manual

Page 371

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–59

Parameter

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

BUC

Temperature

N/A

4 bytes

Query only.

Returns BUCTemperature in the form sxxx, where:

s=sign (+ or –)

xxx=value

Note: This query is only valid when the FSK and BUC power are turned On.

N/A

BUT?

Exception –

600L Emulation:

ODT?

BUT=sxxx

(see Description of

Arguments)

BUC

Phase Lock

Loop

N/A

1 byte, 0 or 1

Query only.

Returns BUC phase lock loop in the form x, where:

0=Locked

1=Unlocked

Note: This query is only valid when the FSK is enabled.

N/A

BPA?

Exception –

600L Emulation:

OLL?

BPA=x

(see Description of

Arguments)

BUC Software

Version

N/A

2 bytes

Query only.

Returns BUC firmware version in the form xx, where:

xx=Value from 00 or 15.

Note: This query is only valid when the FSK and BUC power are turned On.

N/A

BSV?

Exception –

600L Emulation:

OSV?

BSV=xx

(see Description of

Arguments)

BUC

Power Class

N/A

2 bytes

Query only.

Returns BUC Power Class in the form xx, where:

xx=Power Class, in watts.

Note: This query is only valid when the FSK is enabled.

Example: <0/BPC? >0000/BPC=25

N/A

BPC?

Exception –

600L Emulation:

OPC?

BPC=xx

(see Description of

Arguments)

Advertising