Comtech EF Data CDM-625A User Manual

Page 357

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–45

Parameter

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Drop & Insert

DNI=

51 bytes

Command or Query. (D&I only)

Sets or returns D&I in the form ddddddddddddddddddddddddtiiiiiiiiiiiiiiiiiiiiiiiiTL, where:

25 bytes of Drop information (ddddddddddddddddddddddddt) where:

d=24 channels (bytes) defining Drop Timeslot information

t=Drop type: 0=T1-D4, 1=T1-ESF, 2=E1-CCS, 3=E1-CAS, as DTY

25 bytes of Insert information (iiiiiiiiiiiiiiiiiiiiiiiiT) where:

i=24 channels (bytes) defining Insert Timeslot infromation

T=Insert type: 0=T1-D4, 1=T1-ESF, 2=E1-CCS, 3=E1-CAS, as ITY

Typical for Drop or Insert Timeslot definition:

0=Unused

z=Timeslot 0 (zero)

1-9=Timeslots 1 through 9

A=Timeslot 10 through V=Timeslot 31

L=D&I Internal Loop: 0=OFF, 1=ON

Example: <0/DNI=123456789ABC0000000000003123456789ABC00000000000031

(Drop channels 1-12 using timeslots 1-12, and unused channels 13-24. Same for Insert. E1-CAS, D&I types,

Internal Loop ON).

Note: If framing is D&I and data rate is 1920 kbps and DNI Type is E1-CCS or E1-CAS, then channels cannot be

programmed (i.e. FIXED CHANNEL MODE).The DNI? response will display all ‘x’ in the time-slot positions.

DNI=

DNI?

DNI*

DNI#

DNI?

DNI?n

(where n=0 thru 9.

Returns the DNI

portion of 1 of 10

stored

configurations)

DNI=dddddddddddddd

ddddddddddtiiiiiiiiiiiiiiiiiiiiiii

iTL

(see Description of

Arguments)

(Returns current D&I

Configuration)

Drop & Insert

Configuration

(31 channels)

DIC=

67 bytes

Command or Query. (D&I++ only) (Not available in 600/L Emulation mode)

Sets or returns D&I++ in the form dddddddddddddddddddddddddddddddxxsssssssssssssssssssssssssssssssxxL where:

31 bytes of Drop Information (dddddddddddddddddddddddddddddddxx) where:

d=31 channels (bytes) defining Drop Timeslot information

PLUS xx=spares

31 bytes of Insert Information (sssssssssssssssssssssssssssssssxx) where:

s=31 channels (bytes) defining Insert Timeslot information

PLUS xx=spares

Typical for Drop or Insert Timeslot definition:

0=Unused

z=Timeslot 0 (zero)

1-9=Timeslots 1 through 9

A=Timeslot 10 through V=Timeslot 31

L=D&I Internal Loop: 0=OFF, 1=ON

Example: <0/DIC=123456789ABCDEFGHIJKLMNOPQRSTUVxx123456789ABCDEFGHIJKLMNOPQRSTUVxx0

(Drop channels 1-32 using timeslots 1-31 and timeslot zero. Same for Insert. E1-CCS, Internal Loop Off.)

DIC=

DIC?

DIC*

DIC#

DIC?

DIC?n

(where n=0 thru 9.

Returns the DIC

portion of 1 of 10

stored

configurations)

DIC=dddddddddddddd

dddddddddddddddddxx

sssssssssssssssssssss

ssssssssssxxL

(see Description of

Arguments)

Advertising