Note the following:

Selection

Description

[ENTER]Select

Press [ENTER] to accept any updates or changes made on this page – this does not

save the selection to configuration memory, additional action is required.

[ESC] Back

Press [ESC] to exit the current menu and return to the parent submenu.

[F5] Refresh

Press [F5] to discard any changes made on the page and restore all values from the

modem

[F8] Save

Press [F8] to save the currently defined settings to configuration memory

[F9] Add

Press [F9] to add a new index to a table (e.g., VLAN Table, Sect. 9.3.4.4.1)

[F10] Exit

Press [F10] to end the CLI session and close the terminal emulator window

[F11] Delete

Press [F11] to delete an existing index from a table (e.g., VLAN Table,

Sect.9.3.4.4.1)

3) Any menu selection that requires user input

typically features an input dialog window.

Once a menu option is selected, its dialog

window opens and you must use the ↑↓

arrow keys to select a functional choice:

Other dialog windows require entry of a

descriptive alphanumeric string or an

operational numeric value. This example of

the Home > Administration > SNMP: [A]

Contact dialog window shows “Remote A

Site” as the Current Value and prompts you

to enter an alphanumeric New Value:

Type the new parameter, and then press [ENTER] to accept the entry. The dialog window closes

and the CLI returns you to the active configuration page.

4) Each dialog windows provides cues to

ensure proper configuration of the unit. If

you enter an invalid parameter, the CLI

rejects the entry and displays an error

message at the bottom of the window, as

shown in this example:


Here, the CLI rejects the attempted entry of 6 and displays the message “Number is out of

range”. Re-enter a new value (in this example, a value within the acceptable ranges of 0 and

8-32) and then press [ENTER] to continue. Otherwise, press [ESC] to quit the dialog window

and return to the configuration page. You may then proceed with further configuration

updates.