CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–37

Parameter

Command

(Instruction

& Qualifier)

Length of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Rx BERT

Pattern

RBP=

1 byte

Command or Query.

Sets or returns Rx BERT Pattern, in the form x, where:

0=space

1=mark

2=1:1

3=1:2

4=63

5=511

6=2047 (DEFAULT)

7=2047R (or 2047 Alternate)

8=Mil-188

9=2^15-1

A=2^20-1

B=2^23-1

Example: <0/RBP=6 (Rx BERT Pattern is 2047)

RBP=

RBP?

RBP#

RBP?

RBP=x

(see Description of

Arguments)

BERT 10E-3

Error Insert

BKE=

1 byte, 0 or 1

Command or Query.

Inserts 10E-3 BER in the form x, where:

0=Off

1=On

Example: <0/BKE=1

BKE=

BKE?

BKE#

BKE?

BKE=x

(see Description of

Arguments)

BERT Restart

Monitor

BRM=

None

Command only.

This command takes no arguments. Forces restart of the BERT monitor.

Example: <0/BRM=

BRM=

N/A

N/A

BERT Result in

bit errors

N/A

7 bytes, numeric Query only.

Returns BERT monitor results in bit errors.

Note: If bit errors exceed 9999999, then response to query is BRE=9999999.

N/A

BRE?

BRE=xxxxxxx

BERT Result in

average BER

N/A

6 bytes

Query only

Returns the value of the average BER in the form a.bEcx, where:

x.x=Value

Ec=Exponent

x=Indicator of Sync Loss (see Note 1).

Notes:

1) A “*” in last byte means there was a loss of pattern synchronization since last restart, but now is synchronized. A “_”

(space) in last byte means pattern synchronization is achieved.

2) Returns 999999 if there’s no sync in BERT monitor.

Example 1: <0/BRR? >0/BRR=2.8E7 (indicates BER @ 2.8 x 10

-7

and in sync)

Example 2: <0/BRR? >0/BRR=3.4E5* (indicates BER @ 3.4 x 10

-5

, and there was a Sync Loss)

N/A

BRR?

BRR=x.xEcx