Example 1:
08.0,13.5,2.5,1.8,30.0,25.1
means:
(08.0) Minimum Eb/No observed in the measurement interval = 8.0 dB

(13.5) Average Eb/No observed in the measurement interval = 13.5 dB

(2.5) Maximum TPLI observed in the measurement interval = 2.5 dB

(1.8) Average TPLI observed in the measurement interval = 1.8 dB

(30.0) Minimum RSL is observed in the measurement interval = -30.0 dB

(25.1) Average RSL is observed in the measurement interval = -25.1 dB

Example 2:
Loss,04.5,0.0,0.0,29.0,29.0
means:
(Loss) There was a loss of demod lock during the measurement interval

(04.5) Average Eb/No observed in the measurement interval = 4.5 dB

(0.0) Maximum TPLI observed in the measurement interval = 0 dB

(0.0) Average TPLI observed in the measurement interval = 0 dB (which indicates no AUPC

activity, or that AUPC is disabled.)

(29.0) Minimum RSL is observed in the measurement interval = -29.0 dB

(29.0) Average RSL is observed in the measurement interval = -29.0 dB

The presentation of statistics information varies slightly when in IP-ACM or V2-ACM mode. In IP-

ACM Mode:

Stats 115: 22.0,22.0,B,0,0,B,21.6,21.6

17/11/14 12:15:26 Clear-All: No (N/Y)

The modem calculates and then displays, on the top line from left to right, statistics data as

follows:

• (22.0,22.0) First, the SNR is calculated: The minimum SNR value observed during the

measurement interval is provided first, and then the average SNR observed value follows. If
the measured values are ≥16.0 dB, then 16.0 is displayed.

• (B) Next, the Rx ModCod that was current when the entry was logged.

• (0) Maximum Rx ModCod, in hex format, during the measurement interval.

• (0) Minimum Rx ModCod, in hex format, during the measurement interval.

• (B) Number of Rx ModCod changes, in hex format, during the measurement interval.

• (21.6,21.6) Finally, the Receive Signal Level (RSL) is calculated (note that both values are

negative): The minimum value observed in the measurement interval is provided first, and

then the average RSL observed value follows.

In V2-ACM Mode, the modem calculates and then displays, on the top line from left to right,

statistics data as follows: