CDM-625A Advanced Satellite Modem

MN-CDM625A

Front Panel Operation

Revision 3

6–82

Example 1:
08.0,13.5,2.5,1.8,30.0,25.1
means:
(08.0) Minimum Eb/No observed in the measurement interval = 8.0 dB

(13.5) Average Eb/No observed in the measurement interval = 13.5 dB

(2.5) Maximum TPLI observed in the measurement interval = 2.5 dB

(1.8) Average TPLI observed in the measurement interval = 1.8 dB

(30.0) Minimum RSL is observed in the measurement interval = -30.0 dB

(25.1) Average RSL is observed in the measurement interval = -25.1 dB

Example 2:
Loss,04.5,0.0,0.0,29.0,29.0
means:
(Loss) There was a loss of demod lock during the measurement interval

(04.5) Average Eb/No observed in the measurement interval = 4.5 dB

(0.0) Maximum TPLI observed in the measurement interval = 0 dB

(0.0) Average TPLI observed in the measurement interval = 0 dB (which indicates no AUPC

activity, or that AUPC is disabled.)

(29.0) Minimum RSL is observed in the measurement interval = -29.0 dB

(29.0) Average RSL is observed in the measurement interval = -29.0 dB

The presentation of statistics information varies slightly when in IP-ACM or V2-ACM mode. In IP-

ACM Mode:

Stats 115: 22.0,22.0,B,0,0,B,21.6,21.6

17/11/14 12:15:26 Clear-All: No (N/Y)

The modem calculates and then displays, on the top line from left to right, statistics data as

follows:

(22.0,22.0) First, the SNR is calculated: The minimum SNR value observed during the

measurement interval is provided first, and then the average SNR observed value follows. If
the measured values are ≥16.0 dB, then 16.0 is displayed.

(B) Next, the Rx ModCod that was current when the entry was logged.

(0) Maximum Rx ModCod, in hex format, during the measurement interval.

(0) Minimum Rx ModCod, in hex format, during the measurement interval.

(B) Number of Rx ModCod changes, in hex format, during the measurement interval.

(21.6,21.6) Finally, the Receive Signal Level (RSL) is calculated (note that both values are

negative): The minimum value observed in the measurement interval is provided first, and

then the average RSL observed value follows.

In V2-ACM Mode, the modem calculates and then displays, on the top line from left to right,

statistics data as follows: