Comtech EF Data CDM-625A User Manual

Page 740

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Appendix S

Revision 3

S–2

At lower symbol rates, particular care needs to be taken with the frequency accuracy and

stability of the RF carriers. It is your responsibility to determine if sufficient guard band is

built into the frequency plan to avoid carriers moving towards each other and overlapping

at the edges.

Now that you can choose between six different values of Txα, it now becomes

important to match the Rx Alpha (Rxα) accordingly

. Comtech EF Data has analyzed

the effect of mismatching Txα and Rxα, and has concluded that there is little benefit

in providing six values of Rxα. It has been determined that just two values of Rxα –

0.35 and 0.12 – are required to match all six Tx cases.

In order to correctly set Rxα – this assumes that you have knowledge of the Txα being

transmitted – follow these guidelines:

For a Txα of 0.05, 0.10, 0.15, or 0.20, use Rxα = 0.12.

For a Txα of 0.25 or 0.35, use Rxα = 0.35.

If these rules are followed, then the amount of degradation due to mismatch will be < 0.05 dB.

If these rules are not followed, then the amount of degradation due to mismatch can be > 0.3

dB.