Comtech EF Data CDM-625A User Manual

Page 631

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Appendix F

Revision 3

F–25

Once the link is established, a further re-balance, activation or suspension does not require

another person to be present, or independent remote IP access.

2)

Once the ‘normal’ CnC link has been established, determine that the link is stable and that it

has an acceptable link margin at both ends.

3)

Decide, arbitrarily, which is Side ‘A’, and which is Side ‘B’.

4)

From the CDM-625A front panel, select the CONFIG CnC Mode menu:

CnC Mode: APC,Side A,C-Band (Off, On, APC)

Activate? N (Y,N) APC is not active ()

On the top line, use the

▲▼

arrow keys to select the appropriate CnC operating mode.

Available selections are:

Off

On (normal)

APC,Side ‘A’,

C-

Band

APC,Side ‘A’,X-Band

APC,Side ‘A’,Ku-Band

APC,Side ‘A’,Ka-Band

APC,Side ‘B’,

C-

Band

APC,Side ‘B’,X-Band

APC,Side ‘B’,Ku-Band

APC,Side ‘B’,Ka-Band

If it is not known which satellite band is being used, no attempt should be

made to engage CnC-APC.

Once the mode has been selected, press ENTER – do not

select Activate (on the bottom

line) yet.

Note the following:

• If Side ‘A’ is selected at both sides, or Side ‘B’ is selected at both sides, both modems

will display a Frame Sync fault (under Rx faults). No further action is possible until this

error has been corrected.

• If different satellite bands are selected on each side (for instance, Side ‘A’ is Ku-Band,

while Side ‘B’ is C-Band) the modem will display an APC Band Mismatch fault (under Rx

faults). No further action is possible until this error has been corrected.

5)

Based on the known RF terminal equipment in use, determine a value for the maximum

allowed power increase (TPLI

max

) and then set this value. From the CDM-625A front panel,

select the CONFIG Tx Power menu:

Output Power Mode = Cn

C-

Auto-Power-Control

Level = -25.0dBm MaxPwrIncrease=2.5dB ()

Advertising