3 config: rx ( fec, 3 config: rx  fec, Config: rx  fec  reed-solomon on – Comtech EF Data CDM-625A User Manual

Page 151

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Front Panel Operation

Revision 3

6–25

6.2.1.4.3 CONFIG: Rx FEC

Dec=Vit (Vit,Seq,TCM,TPC,LDPC,VFEC,ULL)

Reed-Solomon=Off (Off,On) ()

Use the

◄ ►

arrow keys to select Dec (Decoder) or Reed-Solomon (or Diff Encoder – see Note 1

below). Press ENTER.

On the top line –Use the

▲▼

arrow keys to select an available Decoder option (shown in

parentheses). Press ENTER. Valid selections are:

► None (i.e., uncoded)

► Vit (Viterbi)

► Seq (Sequential)

► TCM (Trellis Coded Modulation)

8-PSK Rate 2/3 only (FAST option)

► TPC (Turbo Product Codec)

(Hardware option)

► LDPC (Low Density Parity

Check) (Hardware option)

► VFEC (VersaFEC)

► VF2L (VersaFEC-2 Long Block)

► VF2S (VersaFEC-2 Short Block)

► ULL (VersaFEC Ultra-Low Latency)

1)

When you select None as the Encoder setting, the bottom line of the display changes

from Reed-Solomon to Diff Encoder (Differential Encoding).

2)

The TPC (Turbo) and LDPC encoding selections display only when the TPC/LDPC

hardware option is installed.

On the bottom line – When Reed-Solomon is present, use the

▲▼

arrow keys to select it as On

or Off. Press ENTER to continue.

CONFIG: Rx FEC Reed-Solomon On

Reed-Solomon Decoding =IESS-310(219/201)

(Standard(126/110),IESS-310(219/201)) ()

Use the

▲▼

arrow keys to select an available parameter. Press ENTER. Depending on the

Framing mode, valid selections are:

IESS-310, open or closed network

219/201

IBS or D&I

126/112

EDMAC or EDMAC2, closed network 200/180
IDR, open network

225/205, 219/201 or 194/178

ESC++ or D&I++, closed network

126/112

Unframed closed network:

○ Comtech standard 220/200

○ Legacy EF Data 225/205, with V.35 scrambling

Otherwise, when Diff Encoder is present, use the

▲▼

arrow keys to select it as On or Off. Press

ENTER to continue.

Advertising