CDM-625A Advanced Satellite Modem

MN-CDM625A

CDM-625A ODU (Transceiver, BUC, LNB) Operation

Revision 3

10–28

ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs

Online/Offline LPOD) Configuration Misc

Misc: AFR=Enabled Ref-Adjust=087 ()

LowFwdPowerThreshold=00.00 Sync-Clock=No

Use the

◄ ►

arrow keys to select a setting, and then use the

▲▼

arrow keys to edit the setting:

Selection

Setting

AFR

(Auto Fault Recovery) This defines how a LPOD reacts to momentary fault conditions:

DisableLPOD mutes when faulted and remain muted.

Enable – LPOD mutes when faulted, and then unmutes once the fault goes away.

Ref-Adjust

Select an Internal 10MHz Reference setting from 000 to 255.
NOTE: The Internal Reference is set in the factory to be very accurate with the default setting

of 087. This setting is provided to compensate for the long-term frequency drift of the

oscillator.

LowFwdPower

Threshold

This sets the threshold for the low forward power alarm/fault. An alarm/fault is triggered if the

forward power drops below the specified value. Set this setting to 00.00 to disable the

threshold.

Sync-Clock

Select YES and press ENTER to synchronize the LPOD RTC to the Modem RTC. (Default is

NO.)

Press ENTER when done.

10.3.3.3.3.4.3.1.2 ODU: FSK-control BUC Advanced-FSK LPOD

(2LPODs Online/Offline LPOD) Monitor

Monitor: Tx Temperature FET Misc

Power-Supplies1 Power-Supplies2

()

To view these read-only LPOD Monitor screens, use the

▲▼

arrow keys to select Tx, Temp,

FETs, Misc, or Power-Supplies, and then press ENTER.

Once any of these screens are viewed, press ENTER or CLEAR to return to the previous menu.

ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs

Online/Offline LPOD) Monitor Tx

Tx: RefTune=009.6 V FwdPower = +20.4 dBm

BUCTune=011.1 V

ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs

Online/Offline LPOD) Monitor Temperature

Temperature: Heat Sink=048.0°C