H.3 setup summary – Comtech EF Data CDM-625A User Manual

Page 646

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Appendix H

Revision 3

H–4

H.3 Setup Summary

To access a distant-end unit:

Designate a Master/Slave pair: Master at the local-end, Slave at the distant-end.

On the local-end unit, enable framing and EDMAC, define the unit as MASTER, and then

enter the bus address. This is constrained to be ‘base 10' meaning that only addresses such

as 10, 20, 30, 40 etc, are allowed.

Choose a unique bus address for the distant-end. This should normally be set to the ‘base

10' address + 1. For example, if the MASTER unit is set to 30, choose 31 for the distant-end

unit.

On the distant-end unit, enable framing and EDMAC, define the unit as SLAVE, and then

enter the bus address.

Set the local-end unit to RS-485 remote control, and set the bus address of this local unit.

The orange “REMOTE” Mode LED on the modem front panel should be lit.

Once the satellite link has been established, connect the M&C User PC, and begin

communications with both the local and distant end units.

EDMAC modes are fully compatible with AUPC modes.