2 odu: fsk-control ( 2csats, 1 odu: fsk-control ( 2csats ( csat#x, 2 odu: fsk-control ( 2csats ( redundancy-box – Comtech EF Data CDM-625A User Manual

Page 489

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

CDM-625A ODU (Transceiver, BUC, LNB) Operation

Revision 3

10–21

10.3.3.3.3.2 ODU: FSK-control 2CSATs

The menus that follow assume that you have selected and the system has identified

two CSATs connected via the Rx IF port and the ODU Redundancy Controller Box.

1:1 Monitor & Control

CSAT#1 CSAT#2 Redundancy-Box

()

Use the

◄ ►

arrow keys to select CSAT#1, CSAT#2, or Redundancy-Box, and then press ENTER.

10.3.3.3.3.2.1 ODU: FSK-control 2CSATs CSAT#X

This submenu and its nested menus are identical in form and function for the

following menu structures:

ODU: FSK-control CSAT

ODU: FSK-control 2CSATs CSAT#X (where CSAT#X = CSAT#1, CSAT#2)

CSAT-5060/050 V1.02

Configuration Monitor Alarms Info ()

Use the

◄ ►

arrow keys to select Configuration, Monitor, Alarms, or Info, and then press

ENTER.

Sect. 10.3.3.3.3.1 ODU: FSK-control CSAT for complete information for these

nested menu choices.

10.3.3.3.3.2.2 ODU: FSK-control 2CSATs Redundancy-Box

Red: Online: ODU2 Mode:Auto Switch:N

TxSw:OK RxSw:OK 5V:5.0 12V:12.0

This menu provides operating mode and switchover controls. You may also view the following

read-only information here:

• Which of the two CSATs in currently online (ODU1 or ODU2);

• Waveguide Switch Tx and Rx status: OK or Ft (fault);

• Redundancy Controller Box 5V and 12V values (to aid trouble-shooting system problems).

To set Operating Mode, use the

◄ ►

arrow keys to select Mode, and then use the

▲▼

arrow

keys to select this mode as Auto or Manual:

Advertising