Warning, Caution – Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 103

Advertising
background image

PC NC Maintenance Manual

The VS-626M5

4-82

Wiring

Operation

• Only commence wiring after verifying that the power supply is turned OFF. Failure to

observe this warning can result in an electric shock or a fire.

• Wiring must be performed only by qualified personnel. Failure to observe this warning

can result in an electric shock or a fire.

• When wiring the emergency stop circuit, check the wiring thoroughly before operation.

Failure to observe this warning can result in personal injury.

• Ensure the ground terminal is grounded. 200V class: ground to 100 or less. Failure to

observe this warning can result in an electric shock or a fire.

• Verify that the converter rated voltage coincides with the AC power supply voltage.

Failure to observe this caution can result in personal injury or a fire.

• Do not perform a withstand voltage test of the inverter and the converter. It may cause

the semi-conductor elements to be damaged.

• Connect the inverter and the converter as shown in the connection diagram, to avoid

damage to the inverter or converter.

• Tighten the terminal screws to the specified tightening torque. Failure to observe this

caution can result in a fire.

• Never connect the AC main circuit power supply to output terminals U/T1, V/T2 and

W/T3. The inverter may be damaged.

• Only turn ON the input power supply after closing the upper and lower cover. Do not

open the covers while current is flowing. Failure to observe this warning can result in

an electric shock.

• Because the Stop button can be disabled by a function setting, install a separate

emergency stop switch. Failure to observe this warning can result in personal injury.

WARNING

CAUTION

WARNING

Advertising