Chapter 4: Troubleshooting

PC NC Maintenance Manual

4-33

Parameter setting is incorrect.

Verify the setting for parameter pm2001 DO. If the setting for
pm2440 is “0” while “pm2001 D0 = 1”, an axis does not move.

Verify the setting for parameters pm5011 D0 to D2.

Set the signal status at the start of the processing when the SKIP
signal is input.

If “0”, processing starts at the point at which 24V faI1s to 0V.

After changing the setting, turn OFF the power once and turn it ON
again.

Verify the setting for parameters pm5010 D0 to D0.

The setting for this parameter determines ENABLE/DISABLE of the con-
trol circuit for the “SKIP” input.

Set “1” to use the skip function.

After changing the setting for this parameter always turn OFF the

power - once and then turn it ON again.

pm2001 D0 = 1

The feedrate in the skip feed mode (G31) is the feedrate set for
parameter pm 2440.

pm2001 D0 = 0

The feedrate in the skip feed mode (G31) is the feedrate speci-
fied with an F code.