Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 140

Advertising
background image

The VS-626M5

PC NC Maintenance Manual

4-119

Note:

6CN 5 to 18 sequence input signals can be input with 0V common, +24V common or external com-
mon. Wiring differs according to input method.

FC3

29

Fault code 3

COM2

30

Fault code signal com-
mon

ZSPD

33

Zero-speed

Open-collector output
Exclusive-use for
24VDC
Load current: 50mA or
less

C1-19

AGR

34

Speed agree

C1-20, C1-38 bit 6

SDET

35

Speed detection

C1-21, C1-40 bit 2

TDET

36

Torque detection

C1-23

TLE

37

Torque limit

_|

ORG

38

Load origin

_|

ORE

39

Orientation completion

C2-09, 10 or C3-09, 10

CHWE

40

Winding selection com-
pletion

_|

FLTL

41

Fault (Open at fault)

_|

TALM

46

Minor fault

_|

COM1

42

Sequence output signal
common

_|

FLTNO

43

Fault contact output
Closed between 43 and
45 at fault
Open between 44 and
45 at fault

Relay contact output
Exclusive-use for
24VDC
Load current: 1A or less

_|

FLTNC

44

FLTCOM

45

SM

47

Speedometer output

0 to +10V Load current:
2mA or less

C1-16, 54

0V

48

0V for speedometer

_|

_|

LM

50

Load ratio meter output

0 to +10V Load current:
2mA or less

C1-17, 54, 18, C1-40 bit 4
C1-38 bit 1, 0
C1-38 bit 7

0V

49

0V for load ratio meter

_|

Table 4.28: Control Circuit Signals (6CN) (Continued)

Signal

Number

Function

Signal Level

Related Constants