Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 49

Advertising
background image

PC NC Maintenance Manual

Chapter 4: Troubleshooting

4-28

Note:

If “1” is set for parameter pm1000 D5, SSTP input is reversed.

(f)

Setting for the parameters related to spindle operation is
incorrect.
Verify the setting for the related parameters.

Figure 4.2: Spindle Rotation

Table 4.15: Input of GRO and SOR and S4-digit Command Analog Voltage

I/O Monitor #3110

S4-digit Command Analog Voltage

D7

D6

GRO Input

SOR Input

0

0

Voltage corresponding to the spindle speed
specified in the NC program.

0

1

Voltage corresponding to parameter pm 1412

1

0

Voltage corresponding to parameter pm 1413

1

1

0V

#3110 D0

GR1

#3110 D1

GR2

#3110 D2

GR3

#3110 D3

GR4

Advertising