Yaskawa YASNAC PC NC Maintenance Manual User Manual
Page 66
Chapter 4: Troubleshooting
PC NC Maintenance Manual
4-45
AL-89 Undefined
parameter
number setting error
Undefined parameter number was specified.
A
AL-8A YENET1200
undefined
command error
Undefined YENET1200 command was specified.
A
AL-8B
Error by which parame-
ter cannot be changed
Error by which I/F card parameter can not be
changed.
A
AL-90
Handshake error
Handshake error between YENET1200 card and
control cards
S
AL-91 YENT1200RAM
defect
1
YENET1200 card memory (RAM) is defective.
S
AL-92 YENT1200RAM
defect
2
YENET1200 card memory (IC) is defective.
S
AL-97 Communication
com-
mand error 1
YENET1200 communication command error
(undefined warning generation)
AL-98 Communication
com-
mand error 2
The YENET1200 communication command error
(orientation tuning can not be done).
AL-99 Communication
com-
mand error 3
YENET1200 communication command error
(memory access can not be done)
AL-9A Communication
com-
mand error 4
The YENET1200 communication command error
(parameter write-in can not be done).
AL-9B Communication
com-
mand error 5
The YENET1200 communication command error
(parameter read-out can not be done).
AL-9C Communication
com-
mand error 6
The YENET1200 communication command error
(disable to change while parameter driving).
AL-9D Communication
com-
mand error 7
YENET1200 communication command error
(parameter command upper and lower limit exag-
gerated)
AL-9E Communication
com-
mand error 8
YENET1200 communication command error
(access number illegality)
AL-9F Communication
com-
mand error 9
YENET1200 communication command error (com-
mand code undefined)
AL-A0
YENET1200 card error
YENET1200 card is abnormal.
[Alarm signal error from card]
1010
A
AL-A1
YENET1200 card RAM
defect
YENET1200 memory (RAM) is defective.
[Common RAM pattern check error at initialization]
1010
S
AL-A2
YENET1200 card I/O
error 1
Data transfer (send and receive) error between
YENET1200 card and control card
[Handshake error at initialization]
1010
S
AL-A3
YENET1200 card I/O
error 2
Data transfer (send and receive) error between
YENET1200 card and control card [WDT count
error at on-line mode]
1010
S
AL-A4
YENET1200 card I/O
error 3
Data transfer (send and receive) error between
YENET1200 card and control card [2ms interrup-
tion time-out error from card]
1010
S
Table 4.18: Alarm Descriptions (Continued)