Heat sink thermistor disconnection – Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 61

Advertising
background image

PC NC Maintenance Manual

Chapter 4: Troubleshooting

4-40

Cause and measures

45:Heat sink thermistor disconnection

Error Contents

The thermistor for the heat sink temperature detection was discon-
nected.

Detection Methods

Cause and measures

The voltage for the heat sink temperature detection is consistent with
the thermistor signal (2CN-10) for the heat sink temperature detection.

If the heat sink temperature is -20ºC or less, the gate is blocked (regen-
eration operation stop), and the alarm is processed.

46, 47:Control card temperature error 1, 2

Error Contents

46: Control card temperature exceeded +80ºC. (minor fault)

47: Control card temperature exceeded +85ºC.

The voltage for the control card temperature detection is consistent
with the thermistor signal for the temperature detection on the control
card.

If the temperature of the control card exceeds 80ºC, the minor fault dis-
play is performed due to control card temperature error 1 (46). The
drive continues.

The minor fault display is released if the temperature of the control
card is 79ºC or less.

Cause Measures

Ambient temperature is high.

Check the ambient temperature.
Improve the cooling.

Control card fault

Exchange unit (exchange control card)

Cause Measures

Ambient temperature is low.

Check the ambient temperature.
Raise the ambient temperature to -20ºC or more.

Thermistor signal conductor disconnec-
tion for cooling fin temperature detection

Check the thermistor wiring.

Control card fault

Unit exchange (control card exchange)