Power circuit low voltage, Control circuit low voltage, Power failure for servo driver – Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 58

Advertising
background image

Chapter 4: Troubleshooting

PC NC Maintenance Manual

4-37

12:Power circuit low voltage

Error Contents

The main circuit input voltage went below the low voltage detection
level while driving.

Detection Methods

The main circuit AC low voltage signal is consistent with the control
card from the R/S phase voltage.

Cause and measures

13:Control circuit low voltage

Error Contents

The control circuit power supply went below the low voltage detection
level.

Detection Methods

The power supply voltage signal for the control circuit is consistent
with the gate driver, and outputs to the control card (2CN-12).

An alarm process is performed if this detection method level continues
5 seconds and the control circuit low voltage detection level is (200V)
or lower.

Cause and measures

14: Power failure for servo driver

Error Contents

The control voltage supplied to the servo driver is abnormal.

Detection Methods

An alarm process is performed and the gate is blocked (regeneration
operation stop) if power supply for the servo driver has continued in the
off position from 24V±5% for 5 seconds.

Cause Measures

Main power supply (R, S, T) voltage is
low.

Adjust the power supply voltage within the specification
value.

Main power supply (R, S, T) open phase,
wavy warp, momentary power failure

Check the power supply ripple.
Normalize the power supply.

Cause Measures

Control power supply (A1, A2) voltage is low.

Check the control power supply voltage.
Adjust the power supply voltage within the specification
value.

Advertising