4.4 Installation

This chapter describes the configuration, location and space when mounting the
VS-626M5 and the VS-656MR5.

Choosing A Location To Mount The Converter

To ensure proper performance and long operating life, follow the recom-
mendations below when choosing a location for installing the VS-626M5
and the VS-656MR5. Make sure the inverter and the converter are pro-
tected from the following conditions:

Extreme cold and heat.

Use only within ambient temperature range: 0

°

C to +55

°

C (32

°

F to

131

°

F)

Rain, moisture.

Oil sprays, splashes

Salt spray.

Direct sunlight. (Avoid using outdoors.)

Corrosive gases or liquids.

Dust or metallic particles in the air.

Physical shock, vibration.

Magnetic noise. (Example: welding machines, power devices, etc.)

High humidity.

Radioactive materials.

Combustibles: thinners, solvents, etc.

• Lift the mounting base. When moving the unit, never lift by the front cover, to avoid

damaging the unit.

• Mount the inverter and the converter on a nonflammable material (i.e., metal). Failure

to observe this caution can result in a fire.

• Install a fan or other cooling device to keep the ambient temperature of inverter and

converter below 55

°

C (131

°

F) and the intake air temperature to heat sink below 45

°

C

(113

°

F). Overheating may cause a fire or damage to the unit.

• Build an external emergency stop circuit that immediately stops operation and shuts

down power in an emergency. Failure to observe this caution may result in personal

injury.

CAUTION