Yaskawa YASNAC PC NC Maintenance Manual User Manual
Page 12
Chapter 1: General Installation and Electrical Connection
PC NC Maintenance Manual
1-9
(4) Heat Generation by Respective Units
Table 1.3: Heat Generation
Unit
Type
Total Heat
Generation (W)
Internal Heat
Generation (W)
Minimum Wind
Velocity for
Cooling
PC NC rack
JZNC-JPCRKM_-_
—
—
—
14” Color CRT with
Touchscreen
JZNC-JPCOP-_ _ _
—
—
—
I/O Module
JANCD-FC810*
29
29
0
JANCD-FC860*
29
29
0
JANCD-FC861*
14.5
14.5
0
Converter
CIMR-MR5N23P7
84
44
2.5
CIMR-MR5N25P5
84
44
CIMR-MR5N27P5
119
61
CIMR-MR5N2011
152
70
CIMR-MR5N2015
204
88
CIMR-MR5N2018
273
108
CIMR-MR5N2022
335
132
CIMR-MR5N2030
392
160
Spindle Inverter
CIMR-MR5N23P7
84
44
2.5
CIMR-MR5N25P5
185
58
CIMR-MR5N27P5
244
77
CIMR-MR5N2011
307
89
CIMR-MR5N2015
454
119
CIMR-MR5N2018
565
144
CIMR-MR5N2022
717
180
CIMR-MR5N2030
869
219
Reactor
UZBA-B 20A 0.53 mH
35
35
0
UZBA-B 30A 0.35 mH
45
45
0
UZBA-B 40A 0.265 mH
50
50
0
UZBA-B 60A 0.18 mH
65
65
0
UZBA-B 80A 0.13 mH
75
75
0
UZBA-B 90A 0.12 mH
90
90
0
UZBA-B 120A 0.09 mH
90
90
0
UZBA-B 160A 0.07 mH
100
100
0