Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 12

Advertising
background image

Chapter 1: General Installation and Electrical Connection

PC NC Maintenance Manual

1-9

(4) Heat Generation by Respective Units

Table 1.3: Heat Generation

Unit

Type

Total Heat

Generation (W)

Internal Heat

Generation (W)

Minimum Wind

Velocity for

Cooling

PC NC rack

JZNC-JPCRKM_-_

14” Color CRT with
Touchscreen

JZNC-JPCOP-_ _ _

I/O Module

JANCD-FC810*

29

29

0

JANCD-FC860*

29

29

0

JANCD-FC861*

14.5

14.5

0

Converter

CIMR-MR5N23P7

84

44

2.5

CIMR-MR5N25P5

84

44

CIMR-MR5N27P5

119

61

CIMR-MR5N2011

152

70

CIMR-MR5N2015

204

88

CIMR-MR5N2018

273

108

CIMR-MR5N2022

335

132

CIMR-MR5N2030

392

160

Spindle Inverter

CIMR-MR5N23P7

84

44

2.5

CIMR-MR5N25P5

185

58

CIMR-MR5N27P5

244

77

CIMR-MR5N2011

307

89

CIMR-MR5N2015

454

119

CIMR-MR5N2018

565

144

CIMR-MR5N2022

717

180

CIMR-MR5N2030

869

219

Reactor

UZBA-B 20A 0.53 mH

35

35

0

UZBA-B 30A 0.35 mH

45

45

0

UZBA-B 40A 0.265 mH

50

50

0

UZBA-B 60A 0.18 mH

65

65

0

UZBA-B 80A 0.13 mH

75

75

0

UZBA-B 90A 0.12 mH

90

90

0

UZBA-B 120A 0.09 mH

90

90

0

UZBA-B 160A 0.07 mH

100

100

0

Advertising