Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 112

Advertising
background image

The VS-626M5

PC NC Maintenance Manual

4-91

Clearances

Install the VS-626M5 and the VS-656MR5 vertically and allow sufficient
clearances for effective cooling.

1.

For the external dimensions and mounting dimensions, refer to
Appendix 2 “Dimensions.”

2.

Allowable intake air temperature to the inverter and the con-
verter:
Open chassis type:0

°

C to +45

°

C (32

°

F to 113

°

F)

Heat sink externally cooling type
Inside heat sink:0

°

C to +45

°

C (32

°

F to 113

°

F)

Inside unit: 0

°

C to +55

°

C (32

°

F to 131

°

F)

3.

Near the heat sink, cooling air speed should be 2.5m/s for effec-
tive cooling (for external cooling type heat sink). See figure
below.

Figure 4.5: Clearances (external cooling type heat sink)

5 mm (0.20 inches)
or more

120 mm (4.72 inches)
or more

Converter

Inverter

Max. 70 mm
(2.76 inches)

Heat Sink

(a) Front View

(b) Side View

Air

Air

120 mm (4.72 inches)
or more