PC NC Maintenance Manual

The VS-626M5

4-138

(2)

Switching Display Functions

Depress the DSPL key on the digital operator to change the mode
of display.

Description

Key

Sequence

Digital Operator

Display

Remarks

Motor speed (U1-01) data is
displayed.

Motor speed data number is
displayed. (Operation status
display has been selected.)

Control signal status of each unit
can be monitored.

Control constants display is
selected.

Control constants are displayed/
set.

Digital operator run command
display is selected.
(Displayed when bits 0 and 1 of
control constant C1-37 are set
ON.)

Use when operating by digital
operator.

The fault number display is
selected. (It is displayed when
a protective function is acti-
vated.)

Contents of currently occurring
fault are displayed.
AL-42 indicates motor thermistor
disconnection is detected.

Fault record display is selected.

Contents of past faults are dis-
played.
1AL30 indicates the last fault is
encoder signal disconnection.

Returns to operation status dis-
play.