PC NC Maintenance Manual

The VS-626M5

4-94

Connection With Peripheral Units

The following shows standard connection of the VS-626M5 with periph-
eral units.

Figure 4.8: Connection with Peripheral Units

Power Supply:
200VAC,
Single-phase

Molded-case Circuit
Breaker (2MCCB) or
Ground Fault
Interrupter

Magnetic Contactor
(2MC)

AC Reactor (L) (Note)

Input Noise Filter

Grounding

Motor

R/L1
S/L2
T/L3

A1/r
A2/t

Connection Bus Bar

Flat Cable

P1N1 Power Supply Cable

U/T1
V/T2
W/T3

Encoder Cable

Z1, Z2, Z3
Motor Cooling Fan
Power Supply

Power Supply:
200VAC, 3-phase(200V class) or
400VAC, 3-phase (400V class)

Molded-case Circuit
Breaker (1MCCB) or
Ground Fault
Interrupter

Magnetic Contactor
(1MC)

Molded-case
Circuit Breake
(3MCCB) or
Ground Fault
Interrupter

Grounding

VS-656MR5
(Converter)

VS-626M5
(Inverter)

Note: Make sure to install AC reactor to protect against converter damage.