Overcurrent, The main circuit fuse fusion – Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 56

Advertising
background image

Chapter 4: Troubleshooting

PC NC Maintenance Manual

4-35

01:Overcurrent

Error Contents

The output current flowed more than the overcurrent detection level.

Detection Methods

If the output current exceeds 180% of the rated current of transistor
(IGBT), the gate is instantaneously blocked (regeneration operation
stop) and the overcurrent detection signal is turned ON.

Cause and measures

04:The main circuit fuse fusion

Error Contents

The main circuit fuse has fused.

Detection Methods

The main circuit fuse signal consists of the gate driver and outputs to
the control card (2CN-6). If the main circuit fuse disconnection detec-
tion signal has been turned ON, the current is intercepted.

Cause and measures

Cause Measures

Main power (R, S, T) open phase, momentary
power failure

Check the main power supply ripple.

Servo/inverter control parameter setting defect Set a correct value referencing with the shipment setting.

Servo and inverter fault

Check the input current of the servo and the inverter.
Exchanged the servo and the inverter.

Reactor selection defect

Perform the proper selection (correspond to the con-
verter capacity).

Converter capacity selection defect

Check the capacity connected to servo and inverter.
Exchange the converter.

Current detection signal connector contact
defect

Check that there are no loose connectors.

Control card fault

Exchange unit exchange (exchange control card)

Cause Measures

Fuse fusion

Check fuse (R phase / T phase) continuity.
Exchange the fuse (R phase / T phase).

Gate driver fault

Confirm that the fuse (R phase and T phase) does not fuse.
Exchange unit (gate driver exchange)

Control card fault

Exchange unit (control card exchange)

Advertising