Overcurrent, The main circuit fuse fusion – Yaskawa YASNAC PC NC Maintenance Manual User Manual
Page 56
Chapter 4: Troubleshooting
PC NC Maintenance Manual
4-35
01:Overcurrent
Error Contents
The output current flowed more than the overcurrent detection level.
Detection Methods
If the output current exceeds 180% of the rated current of transistor
(IGBT), the gate is instantaneously blocked (regeneration operation
stop) and the overcurrent detection signal is turned ON.
Cause and measures
04:The main circuit fuse fusion
Error Contents
The main circuit fuse has fused.
Detection Methods
The main circuit fuse signal consists of the gate driver and outputs to
the control card (2CN-6). If the main circuit fuse disconnection detec-
tion signal has been turned ON, the current is intercepted.
Cause and measures
Cause Measures
Main power (R, S, T) open phase, momentary
power failure
Check the main power supply ripple.
Servo/inverter control parameter setting defect Set a correct value referencing with the shipment setting.
Servo and inverter fault
Check the input current of the servo and the inverter.
Exchanged the servo and the inverter.
Reactor selection defect
Perform the proper selection (correspond to the con-
verter capacity).
Converter capacity selection defect
Check the capacity connected to servo and inverter.
Exchange the converter.
Current detection signal connector contact
defect
Check that there are no loose connectors.
Control card fault
Exchange unit exchange (exchange control card)
Cause Measures
Fuse fusion
Check fuse (R phase / T phase) continuity.
Exchange the fuse (R phase / T phase).
Gate driver fault
Confirm that the fuse (R phase and T phase) does not fuse.
Exchange unit (gate driver exchange)
Control card fault
Exchange unit (control card exchange)