Chapter 4: Troubleshooting

PC NC Maintenance Manual

4-27

(d)

Start interlock signal is input.
If I/O monitor #3004 D2 = 1, start interlock is ON.
Normal: #3004 D2 = 0

(e)

Axis interlock is input.
Verify I/O monitor #3087 D0 to D4.
Normal: #3078 D0 to D4 = 1

(f)

Setting of the servo system is incorrect.
Verify whether the axes can be moved manually.

(8)

Spindle Rotation is Impossible

(a)

Error in a program (no S command or no spindle start M
code)
Verify the contents of the program on the [RUN] screen.

(b)

Start signal has not been input.
Verify the output signals (#1100s) on the I/O monitor screen.

(c)

Spindle rotation command has not been output.
Verify #3654 to #3656 on the 110 monitor screen.

(d)

The spindle drive is in the alarm status.
Verify the alarm indication of the spindle drive.

(e)

Combination of GRO and SOR is incorrect, or “0’ is input for
parameter pm1412 or pm1413.

1

1

0

0

0

280%

1

1

0

0

1

300%

1

1

0

1

0

340%

1

1

0

1

1

380%

1

1

1

0

0

420%

1

1

1

0

1

460%

1

1

1

1

0

500%

1

1

1

1

1

540%

Table 4.14: I/O Monitor and Feedrate Override (Continued)