Chapter 4: Troubleshooting

PC NC Maintenance Manual

4-43

An error number of AL-80 ~ AL-9F is displayed only by the host NC unit.
They are not displayed in a digital operator of VS-626M5.

Table 4.18: Alarm Descriptions

Number Name

Content

Fault

Code

Rank

AL-01

Overcurrent

Output current flowed more than the overcurrent
detection value or the inverter output (load) was
short-circuit.

0000 A

AL-02

Ground fault

Ground fault current in the inverter output side
exceeded the ground fault detection level.

0000 A

AL-04

Main circuit fuse open
circuit

The DC circuit fuse fused.

0000

A

AL-05

Inverter output overload Output current flowed more than 120% /min. at 30

min. rating.

0000 A

AL-10

Converter error

An error occurred in the converter unit.

0001

A

AL-11

Main circuit overvoltage Main circuit DC voltage exceeded the overvoltage

setting value.

0001 A

AL-12

Main circuit low voltage Main circuit DC voltage went below the low voltage

detection level while driving.

0001 A

AL-13

Control circuit low volt-
age

Control circuit power supply went below the low
voltage detection level.

0001 A

AL-20

Wiring switch over drive
defect

Wiring switch over drive did not complete in setting
time or less.

0010 A

AL-21 Emergency

stop

drive

defect

Did not stop within ten seconds after the specified
the emergency stop.

0010 A

AL-30

Encoder signal discon-
nection

Motor encoder signal conductor disconnection/
improper connection.

0011 A

AL-31

Overspeed of motor

Motor speed exceeded 120% of setting rated
speed.

0011 A

AL-32

Speed over-deviation

Speed became 50% or less of the command value. 0011

A

AL-33

Load error

Inverter output opening (speed feedback is 0.)

0011

A

AL-40

Motor overheat (minor
fault)

Motor temperature exceeded the upper limit.

0100

B

AL-41

Motor overheating 2

Motor temperature exceeded the upper limit for
one minute or more.

0100 A

AL-42 Motor

thermistor

discon-

nection

Thermistor for the motor temperature detection
was disconnected.

0100 A

AL-43

Heat sink overheating
(minor fault)

Heat sink temperature exceeded the upper limit.

0100

B

AL-44

Heat sink overheating 2 Heat sink temperature exceeded the upper limit for

one minute or more.

0100 A

AL-45

Heat sink thermistor dis-
connection

Thermistor for the heat sink temperature detection
was disconnected.

0100 A