The VS-626M5
PC NC Maintenance Manual
4-155
Control circuit I/O
fault 1
Data transmission error
between CPUs.
Replace the control PC board.
_›_›_œ_›
Control circuit I/O
fault 2
_›_›_œ_›
Control circuit I/O
fault 3
_›_›_œ_›
Motor code
selection error
Selected motor code (C1-25)
does not match inverter
capacity (C1-56).
Check motor model, motor code
(C1-25), inverter model and
inverter capacity selection (C1-
56).
_›_›_›_œ
Motor code
unrecorded
Motor code set in C1-25 is not
recorded.
Check motor model and motor
code (C1-25).
Check setting list for correct
PROM version of motor code
(C1-25).
_›_›_›_œ
Constant setting
range error
Memory (EEPROM) data
exceeded upper/lower limit.
Check that rated speed (C1-26)
is within setting range.
Check control constants.
Replace the control PC board.
_›_›_›_œ
Orientation card
mismatch
Selected orientation bit does
not match orientation card.
Check orientation card model
and orientation selection signal
(bit 0 of C1-39).
Replace the orientation card.
_›_›_›_œ
Inverter capacity
selection error
Selected inverter capacity
(C1-56) does not match the
unit.
Check inverter model and
inverter capacity selection (C1-
56).
_›_›_›_œ
ROM error
Memory (PROM) error
Replace the control PC board.
_›_›_›_›
EEPROM error 1
Memory (EEPROM) error
_›_›_›_›
EEPROM error 2
_›_›_›_›
EEPROM error 3
_›_›_›_›
EEPROM error 4
_›_›_›_›
Control circuit fault
1 (operator trans-
mission
error)
Transmission between the
inverter and the digital opera-
tor cannot be established until
5 seconds after supplying
power. Built-in memory fault,
WDT activated.
Insert the digital operator con-
nector again.
Check the wiring of power sup-
ply signal line of 1CN.
Replace the control PC board.
_\
Control circuit fault
2 (operator trans-
mission
error)
Transmission between the
inverter and the digital opera-
tor is established once after
supplying power, but later
transmission fault continues
for more than 2 seconds.
WDT time exceeded.
_\
Table 4.37: Fault Diagnosis and Inverter Corrective Actions (Continued)
Fault Number
Name
Contents
Corrective Action
Fault Code