The VS-626M5

PC NC Maintenance Manual

4-155

Control circuit I/O
fault 1

Data transmission error
between CPUs.

Replace the control PC board.

_›_›_œ_›

Control circuit I/O
fault 2

_›_›_œ_›

Control circuit I/O
fault 3

_›_›_œ_›

Motor code
selection error

Selected motor code (C1-25)
does not match inverter
capacity (C1-56).

Check motor model, motor code
(C1-25), inverter model and
inverter capacity selection (C1-
56).

_›_›_›_œ

Motor code
unrecorded

Motor code set in C1-25 is not
recorded.

Check motor model and motor
code (C1-25).
Check setting list for correct
PROM version of motor code
(C1-25).

_›_›_›_œ

Constant setting
range error

Memory (EEPROM) data
exceeded upper/lower limit.

Check that rated speed (C1-26)
is within setting range.
Check control constants.
Replace the control PC board.

_›_›_›_œ

Orientation card
mismatch

Selected orientation bit does
not match orientation card.

Check orientation card model
and orientation selection signal
(bit 0 of C1-39).
Replace the orientation card.

_›_›_›_œ

Inverter capacity
selection error

Selected inverter capacity
(C1-56) does not match the
unit.

Check inverter model and
inverter capacity selection (C1-
56).

_›_›_›_œ

ROM error

Memory (PROM) error

Replace the control PC board.

_›_›_›_›

EEPROM error 1

Memory (EEPROM) error

_›_›_›_›

EEPROM error 2

_›_›_›_›

EEPROM error 3

_›_›_›_›

EEPROM error 4

_›_›_›_›

Control circuit fault
1 (operator trans-
mission
error)

Transmission between the
inverter and the digital opera-
tor cannot be established until
5 seconds after supplying
power. Built-in memory fault,
WDT activated.

Insert the digital operator con-
nector again.
Check the wiring of power sup-
ply signal line of 1CN.
Replace the control PC board.

_\

Control circuit fault
2 (operator trans-
mission
error)

Transmission between the
inverter and the digital opera-
tor is established once after
supplying power, but later
transmission fault continues
for more than 2 seconds.
WDT time exceeded.

_\

Table 4.37: Fault Diagnosis and Inverter Corrective Actions (Continued)

Fault Number

Name

Contents

Corrective Action

Fault Code