Yaskawa YASNAC PC NC Maintenance Manual User Manual
Page 165
PC NC Maintenance Manual
The VS-626M5
4-144
Set the speed reference in digital operator operation to d1-02.
The following table shows the keys used in the digital operator
operation mode. Rotating direction is selected with the FWD/
REV key and run/stop by the RUN or STOP key.
Description
Key
Sequence
Digital Operator
Display
Remarks
Select d1-01.
—
Select d1-02.
—
Display d1-02 data
contents.
—
Set speed reference
(25%).
The speed reference is displayed as a
percentage of rated speed settings
(C1°26). For a rated speed of
6000rpm, 25% reference becomes
1500rpm reference.
—
—
—
Write-in set value.
Displayed for 0.5 seconds
—
—
Returns to previous display before
write-in.
Table 4.33: Key Operations in Digital Operator Operation Mode
Key
Name
Function
Emergency stop key When the key is depressed, the current is shut off
after decelerating to a stop.
Jog run key
Jog run can be performed when the key is held
down. [Runs at 5% reference of rated speed set-
ting (C1-26).]
FWD/REV run key
FWD/REV run is switched when the key is
depressed. (FWD/REV LED lights alternately.)
Run command key
Depress the key to start operation. (Red LED on
the left lights during run.)
Stop command key
Depress the key to stop operation. (Red LED on
the left lights during stop.)
DSPL
DATA
ENTER
D
RESET
D
DATA
ENTER
D
DRIVE
PRGM
JOG
FWD
REV
JOG
RUN
JOG
STOP