PC NC Maintenance Manual

The VS-626M5

4-144

Set the speed reference in digital operator operation to d1-02.

The following table shows the keys used in the digital operator
operation mode. Rotating direction is selected with the FWD/
REV
key and run/stop by the RUN or STOP key.

Description

Key

Sequence

Digital Operator

Display

Remarks

Select d1-01.

Select d1-02.

Display d1-02 data
contents.

Set speed reference
(25%).

The speed reference is displayed as a
percentage of rated speed settings
(C1°26). For a rated speed of
6000rpm, 25% reference becomes
1500rpm reference.

Write-in set value.

Displayed for 0.5 seconds

Returns to previous display before
write-in.

Table 4.33: Key Operations in Digital Operator Operation Mode

Key

Name

Function

Emergency stop key When the key is depressed, the current is shut off

after decelerating to a stop.

Jog run key

Jog run can be performed when the key is held
down. [Runs at 5% reference of rated speed set-
ting (C1-26).]

FWD/REV run key

FWD/REV run is switched when the key is
depressed. (FWD/REV LED lights alternately.)

Run command key

Depress the key to start operation. (Red LED on
the left lights during run.)

Stop command key

Depress the key to stop operation. (Red LED on
the left lights during stop.)