PLC Parameters Screen

The labelling scheme for the Utilities: PLC Parameters screen is similar to
that for the Utilities: PLC Diagnosis screen. Labels for the Utilities: PLC
Parameters
screen are stored in the text file ‘c:\ypcnc\data-
base\plc_param.txt’.

The file has an entry for each labelled bit, and the entry contains address,
label, and detail.

Below is an example of a typical label file.

; This file is for PLC parameter label table for PLC parameter

screen.

; Specify the PLC parameter number by pound code and 5 digit

address.

; Specify the address name up to 7 characters.

; ; is for comment.

; Example

#70000

ATC 8

; ATC 8 pot

#70001

ATC16

; ATC16 pot

#70002

APC op

; APC option

#70003

Robot

; Robot option