Periodic Inspection
The VS-626M5 and the VS-656MR5 function longer if they are kept clean,
cool and dry, while observing the precautions listed in
Par. 2.1
. Check for
tightness of electrical connections, discoloration, or other signs of over-
heating or aging. Use the table below
as your inspection guide. Before ser-
vicing, turn OFF the AC main circuit power and ensure that the CHARGE
LED and 7-segment LED are OFF.
Table 4.34: Periodic Inspection
Component
Check
Corrective Action
Inverter/
Converter
External Terminals,
Unit Mounting Bolts,
Connectors, etc.
Loose screws
Tighten.
Loose connectors
Tighten.
Heat Sink
Build-up of dust and dirt
Blow with dry compressed air of
39.2_10
4
to 58.8_10
4
Pa (4 to
6kg_cm
2
) pressure.
Printed Circuit Board Accumulation of conductive
dust or oil
Blow with dry compressed air of
39.2_10
4
to 58.8_10
4
Pa (4 to
6kg_cm
2
) pressure. If dust and oil
cannot be removed, replace the
board.
Cooling Fan
For abnormal noise and vibra-
tion
Whether the cumulative opera-
tion time exceeds 20,000
hours or not.
Replace the cooling fan.
Power Elements
Accumulation of dust and dirt
Blow with dry compressed air of
39.2_10
4
to 58.8_10
4
Pa (4 to
6kg_cm
2
) pressure.
Smoothing
Capacitor
Discoloration or odor
Replace the capacitor or converter
unit.
Related to
Bearing
Bearing Noise
Abnormal noise or increase of
noise level
Replace the bearing.
Vibration
Abnormal vibration
Bearing
Temperature
Abnormal temperature rise
Grease
No leakage
Remove the cause to recover.
Motor
Cooling
Fan
Operation Status
Normal operation
Remove the cause of fan halt or
replace the fan if a fault is found.