Periodic Inspection

The VS-626M5 and the VS-656MR5 function longer if they are kept clean,
cool and dry, while observing the precautions listed in

Par. 2.1

. Check for

tightness of electrical connections, discoloration, or other signs of over-
heating or aging. Use the table below

as your inspection guide. Before ser-

vicing, turn OFF the AC main circuit power and ensure that the CHARGE
LED and 7-segment LED are OFF.

Table 4.34: Periodic Inspection

Component

Check

Corrective Action

Inverter/
Converter

External Terminals,
Unit Mounting Bolts,
Connectors, etc.

Loose screws

Tighten.

Loose connectors

Tighten.

Heat Sink

Build-up of dust and dirt

Blow with dry compressed air of

39.2_10

4

to 58.8_10

4

Pa (4 to

6kg_cm

2

) pressure.

Printed Circuit Board Accumulation of conductive

dust or oil

Blow with dry compressed air of

39.2_10

4

to 58.8_10

4

Pa (4 to

6kg_cm

2

) pressure. If dust and oil

cannot be removed, replace the
board.

Cooling Fan

For abnormal noise and vibra-
tion
Whether the cumulative opera-
tion time exceeds 20,000
hours or not.

Replace the cooling fan.

Power Elements

Accumulation of dust and dirt

Blow with dry compressed air of

39.2_10

4

to 58.8_10

4

Pa (4 to

6kg_cm

2

) pressure.

Smoothing
Capacitor

Discoloration or odor

Replace the capacitor or converter
unit.

Related to
Bearing

Bearing Noise

Abnormal noise or increase of
noise level

Replace the bearing.

Vibration

Abnormal vibration

Bearing
Temperature

Abnormal temperature rise

Grease

No leakage

Remove the cause to recover.

Motor
Cooling
Fan

Operation Status

Normal operation

Remove the cause of fan halt or
replace the fan if a fault is found.