AL-E4:Inverter capacity selection error
Error Contents
The selected inverter capacity (C1-56) and unit don’t match.
Cause and measures
AL-F0:ROM is defective.
Error Contents
The memory (PROM) is defective. [Sum check error]
Cause and measures
AL-F1(F1): EEPROM is defective 1
Error Contents
The memory (EEPROM) is defective. [Verification error at initializa-
tion]
Cause and measures
Cause Measures
Inverter capacity selection (C1-56)
setting is defective.
Confirm the inverter type, and inverter capacity
selection (C1-56).
Control card fault
Exchange unit (exchange control card)
Gate driver fault
Exchange unit (exchange gate driver)
Cause Measures
PROM is defective.
Exchange PROM on the control card with a non-defective
one.
Control card fault
Exchange unit (exchange control card)
Cause Measures
Control card fault
Exchange unit (exchange control card)