1.2 General Specifications

The enclosure must be designed to meet all of the following conditions.

Note:

Avoid installing the control panel in a location subject to direct sunlight, near heat generating

Table 1.1: Specifications

Item

Specifications

Ambient Conditions

Temperature*

Storage and
Transportation

-15

o

C to +65

o

C

Operating
(around
enclosure)

PC NC unit
I/O module
Servo Amplifier
14” Color monitor with touch
screen

0

o

C to +53

o

C

Humidity

20% to 80% RH (with operation)
10% to 90% RH (with non-operation)

Vibration during operation

Less than 4.9m/s

Others

Free from dust, coolant, or organic solvent

PC NC Unit input power supply +24VDC+10% 180V-264VAC

Power Supply Unit
UPS000004

Input power supply voltage: 180V ~ 264VAC
Frequency: 47Hz to 63Hz
Momentary interruption: 0.5 cycle (0VDC)