2 general specifications – Yaskawa YASNAC PC NC Maintenance Manual User Manual
Page 8
Chapter 1: General Installation and Electrical Connection
PC NC Maintenance Manual
1-5
Connector Layout (PC Side)
Figure 1.5: Connector Layout of the PC NC CPU Rack (top view)
1.2 General Specifications
The enclosure must be designed to meet all of the following conditions.
Note:
Avoid installing the control panel in a location subject to direct sunlight, near heat generating
Table 1.1: Specifications
Item
Specifications
Ambient Conditions
Temperature*
Storage and
Transportation
-15
o
C to +65
o
C
Operating
(around
enclosure)
PC NC unit
I/O module
Servo Amplifier
14” Color monitor with touch
screen
0
o
C to +53
o
C
Humidity
20% to 80% RH (with operation)
10% to 90% RH (with non-operation)
Vibration during operation
Less than 4.9m/s
Others
Free from dust, coolant, or organic solvent
PC NC Unit input power supply +24VDC+10% 180V-264VAC
Power Supply Unit
UPS000004
Input power supply voltage: 180V ~ 264VAC
Frequency: 47Hz to 63Hz
Momentary interruption: 0.5 cycle (0VDC)