2.7Designing a Protective Sequence

— 2-61 —

The following table provides details of the alarm displays.

Alarm Display and Alarm Code Output

Alarm

Servo

Alarm

Alarm Type

Alarm Description

Alarm

Display

Alarm

(ALM)

Output

Alarm Type

Alarm Description

OFF

Parameter

error

An absolute encoder error occurred or parameter is

faulty.

OFF

Overcurrent Overcurrent flowed thorough the main circuit.

Servopack overheated.

OFF

Position

error pulse

overflow

The number of pulses in error counter has exceeded

the preset value.

OFF

Overspeed

Motor speed has exceeded the maximum allowable

speed.

OFF

Overload

Motor and Servopack are overloaded.

OFF

Encoder

error

An error occurred in the number of feedback pulses

from the Encoder.

OFF

Overrun

Disconnec-

tion of en-

coder signal

line

Overrun occurred due to motor or encoder signal

wiring faults.

Encoder signal line is disconnected.

Unde-

Digital

Operator

transmis-

Communication error occurred between Digital Oper-

ator and Servopack.

Unde-

fined

transmis-

sion error

ON

No error

---

ON:Output transistor is ON
OFF: Output transistor is OFF
* : Displays an alarm category number.
For details, refer to Appendix D List of Alarm Displays.

When the servo alarm (ALM) is output, eliminate the cause of the alarm and set the following
/ALMRST input signal at high level (+24 V) to reset the alarm state.

Input /ALMRST CN1-*1

Alarm Reset

For Speed/Torque

Control and

Position Control

This signal is used to reset the servo alarm state.

2