5 cable with cn1 connector at one end only, 6 circuit breaker – Yaskawa Sigma Mini User Manual

Page 211

Advertising
background image

4.6Specifications and Dimensional Drawings of Peripheral Devices

— 4-61 —

4.6.5 Cable with CN1 Connector at One End Only

The following cables do not have a connector at the host controller end. The loose wires at the
host controller end are labelled with the terminal numbers.

Type

L mm (feet)

JZSP-VFI01-01

1000

+100

0

(3.3

+0.33

0

)

JZSP-VFI01-03

3000

+100

0

(10

+0.33

0

)

Shielded cable

Connector: 54331-0201

Terminal number labels

Label

Shielded Cable:
AWG28 x 10 P, UL20276

Shrink tube

40 (1.57)

L

⋅⋅⋅

4.6.6 Circuit Breaker

The customer should purchase a circuit breaker (MCCB) of appropriate capacity to protect
the power lines.

Recommended Product

Ground fault detector for motor protection manufactured by

Mitsubishi Electric Co. Ltd.

Type: MN50-CF

Rated Current: 7.1 A

4