3.1Basic Operations

— 3-9 —

3.1.6 Operation in Monitor Mode

The monitor mode allows the reference values input into the Servopack, I/O signal status,
and Servopack internal status to be monitored.

The monitor mode can be set during motor operation.

Using Monitor Mode

The example below shows how to display 1500, the contents of monitor number Un-00.

1) Press

DSPL

SET

to select monitor mode.

2) Press the

and

keys to select the

monitor number to display.

3) Press

DATA

ENTER

to display the data for the mon-

itor number selected at step 2.

4) Press

DATA

ENTER

once more to display the moni-

tor number again.

Meaning of Monitor Mode Display

Keys to Monitor Mode Displays are shown in the following table.

The display differs between the speed/torque control and position control.

Speed/Torque Control

Monitor

Number

Monitor Display

Actual motor speed

Units: min

−1

.

Input speed reference

Units: min

−1

.

Internal torque reference

Units: %

(with respect to rated torque)

Number of pulses from motor

U-phase edge

Units: pulses

Electrical angle

Units: deg

Internal status bit display

3

Monitor

Mode

Monitor

Number

Data

Monitor

Number

Data

Speed/Torque

Internal Status

Bit Display

See following table.