APPLICATIONS

2.2.5 Electronic Gear cont.

— 2-26 —

6) Set the electronic gear ratio in the parameters below.

Reduce the electronic gear ratio

B

A

to their lowest terms so that both A and B are an

integer smaller than 65535, then set A and B in the following parameters.

B

A

Cn-24

RATB Electronic gear ratio (numerator)

Cn-25

RATA Electronic gear ratio (denominator)

Cn-24

RATB

Electronic Gear Ratio

Numerator

Unit:

None

Setting

Range: 1

to 65535

Factory

Setting: 4

For Position Control

Cn-25

RATA

Electronic Gear Ratio

Denominator

Unit:

None

Setting

Range: 1

to 65535

Factory

Setting: 1

For Position Control

These parameters are for position control only.

Set the electronic gear ratio according to machine
specifications.

Electronic gear ratio

B

A

= Cn-24

Cn-25

B =

[(Number of encoder pulses) x 4] x [Motor shaft rotating speed]

A =

[Reference unit (load travel distance per revolution of load shaft)] x [Load shaft ro-
tating speed]

The parameter settings must meet the following condition:

0.01

B

A

100

The electronic gear settings are now complete.

2

Input

reference

pulse

Servopack

Servomotor

Electronic

gear

Advertising