2 applications, 1 operation in alarm traceback mode – Yaskawa Sigma Mini User Manual

Page 137

Advertising
background image

3.2Applications

— 3-13 —

3.2

Applications

This section describes the applications of the Digital Operator’s basic operations for

operating and adjusting the motor. Be sure to read 3.1 Basic Operations before reading

this section.

3.2.1 Operation in Alarm Traceback Mode

The alarm traceback mode displays up to ten alarms that occurred previously. Allowing con-
firmation of what alarm occurred when, is a useful aid to speed up troubleshooting.

The alarm traceback data is not cleared when the alarm is reset or when the Servopack pow-
er is turned OFF. The alarm traceback data does not prevent the Servopack from operating
properly. Use the special operation to clear alarm traceback data to clear the data. Refer to
3.2.6 Clearing Alarm Traceback Data for details.

Alarm Sequence Number

Alarm Code

The higher the number,

the older the alarm data

See the table of

alarms on page 3-14.

Alarm Confirmation

Use the following procedure to determine which alarms occurred previously.

1) Press

DSPL

SET

to select the alarm trace-

back mode.

2) Press the

and

keys to scroll the

alarm sequence numbers up and down
and display information on previous
alarms. The higher the left-hand digit
(alarm sequence number), the older the
alarm data.

3

Alarm Traceback Mode

Older

Newer

Advertising