Yaskawa Sigma Mini User Manual

Page 272

Advertising
background image

— C-7 —

For Position Control

List of Parameters (Memory Switch Setting)

Parameter

N

Bit No.

Setting

Factory

S

i

No.

0

1

y

Setting

Input signal

enable/disable

Cn-01

0

Uses servo ON input.

Does not use servo ON input.

Servo is always ON.

0

Not used

1, 2, 3,

4, 5, 6,

7, 8, 9

Not used (Do not set.)

0

Operation

performed at

servo OFF

A

Clears error pulse when servo

is turned OFF.

Does not clear error pulse when

servo is turned OFF.

0

Mode switch

selection

B

Uses mode switch function as

set in bits D and C of Cn-01.

Does not use mode switch

function.

0

se ect o

D¡C

0¡0: Uses internal torque reference as a condition.

(Level setting: Cn-0C)

0¡1: Uses speed reference as a condition. (Level setting: Cn-0D)

1¡0: Uses acceleration as a condition. (Level setting: Cn-0E)

1¡1: Does not use mode switch function.

0¡0

Not used

E

Not used (Do not set)

0

INHIBIT function

Always receives pulse

reference.

Enables INHIBIT function.

0

Rotation direction

selection

Cn-02

0

Defines counterclockwise

(CCW) rotation as forward

rotation.

Defines clockwise (CW) rotation

as forward rotation (reverse

rotation mode).

0

Home position

error processing

selection

1

Detects home position error.

Does not detect home position

error.

0

Not used

2

Not used (Do not set)

0

Reference pulse

form selection

5¡4¡3

0¡0¡0: Sign + Pulse

0¡0¡1: CW + CCW

0¡1¡0: Phase A + Phase B (x 1 multiplication)

0¡1¡1: Phase A + Phase B (x 2 multiplication)

1¡0¡0: Phase A + Phase B (x 4 multiplication)

0¡0¡0

Not used

6, 7, 8

Not used (Do not set)

0

Error counter

clear signal

A

Clears the error counter when

an error counter clear signal is

at high level.

Clears the error counter when

the leading edge of an error

counter clear signal rises.

0

Integration time

constant setting

unit

B

1 ms

0.01 ms

0

Torque reference

filter

C

Primary

Secondary

0

Reference pulse

logic

D

Does not invert reference pulse

logic.

Inverts reference pulse logic.

Others

E

Displays position error Un-08 in

x 1 reference units while in

monitor mode.

Displays position error Un-08 in

x 100 reference units while in

monitor mode.

0

F

Line driver

(Maximum reference pulse

frequency: 450 kpps)

Open collector

(Maximum reference pulse

frequency: 200 kpps)

0

Note

For the Cn-01 and Cn-02 memory switches, always turn OFF the power, and then turn ON
again to validate the new settings.

C