Input +24vin cn1-9, Output → out2 cn1-7 – Yaskawa Sigma Mini User Manual

Page 66

Advertising
background image

APPLICATIONS

2.2.4 Contact I/O cont.

— 2-22 —

Setting

Meaning

0

/S-ON (Servo ON)

1

/P-CON (proportional control reference)

2

/ALMRST (alarm reset)

3

/CL (torque limit)

Input +24VIN CN1-9

External I/O Power Supply

For Speed/Torque

Control and

Position Control

This external power supply input terminal is com-
mon to the following contact input signals:

Contact Input Signals: /S-ON

/P-CON
/ALMRST
/CL

Contact Output Signal Terminal Connections

Connect contact output signal terminal connections as follows:

These output signals are used
to indicate Servopack operation

status.

Servopack

Photocoupler output
Per output
Maximum: operational

voltage: 30 VDC

Maximum output current:

50 mA DC

Photocoupler

CN1-7

CN1-3

CN1-8

SG-COM

OUT2

ALM

MAX 50mA

MAX 50mA

+24V

I/O power

supply

Note Provide an external I/O power supply separately.

There are no power terminals to which the Servopack outputs signals externally.
Yaskawa recommends that this external power supply be the same type as for the
input circuit.

Output OUT2 CN1-7

Output

Signal

Selection 2

Factory Setting: 3

For Speed/Torque

Control and

Position Control

2

Servopack

Connect an external I/O power supply.

CN1-19

I/O power

supply

Advertising