SERVO SELECTION AND DATA SHEETS

4.3.1 Ratings and Specifications

— 4-24 —

SGDF Servopack

B9CP

B5CP

B3CP

Performance

Bias Setting

0 to 450 min

−1

. (Setting resolution: 1 min

−1

.)

Feed Forward Compensation 0% to 100% (Setting resolution: 1%)
Position Complete Width

Setting

0 to 250 reference units.
Reference unit: minimum unit of position data

which moves load

Input Signal

Reference

Pulse

Type

SIGN + PULSE train, 90° phase difference

2-phase pulse, (Phase-A + Phase-B), CCW

pulse+CW pulse

Pulse Form

Line driver (+5 V level), open collector (+5 V or

+12 V level)

Pulse Frequency 0 to 450 kpps

Control Signal

CLEAR (input pulse form identical to reference

pulse)

I/O Signals

Position

O

Output Form

Phase-A, -B, -C line driver output

/

g

Output

Frequency

Dividing Ratio

(16 to N) /N N=1024*

2

Sequence Input (2 Inputs)

Servo ON, P drive, alarm reset, current control

(select from parameters)

Sequence Output

(2 Outputs)

Current limit detection, TGON, positioning

complete, brake interlock, servo alarm (servo

alarms are fixed and other settings are selected

from parameters)

Protective Functions

Overcurrent, overload, overspeed, overrun

prevention, CPU error, encoder error, overflow

Indicators

LED indicators

Red: Alarm, Green: Ready

Others

Brake interlock signal output, JOG run,

autotuning, electronic gear

*