LIST OF PARAMETERS

— C-6 —

Category

Remarks

Factory

Setting

Upper

Limit

Lower

Limit

Unit

Name

Code

Parameter

No.

Pulse

R l

d

Cn-0A

PGRAT

PG dividing ratio P/R

16

32768

2048

Related

Constants

Cn-11

PULSNO

Number of

encoder pulses

P/R

513

32768

2048

Cn-24

RATB

Electronic gear

ratio (numerator)

1

65535

4

See note 3

Cn-25

RATA

Electronic gear

ratio

(denominator)

1

65535

1

See note 3

Other

Constants

Cn-0C

TRQMSW

Mode switch

(torque

reference)

%

0

Maximum

torque

200

Cn-0D

REFMSW

Mode switch

(speed

reference)

min

−1

0

Maximum

speed

0

Cn-0E

ACCMSW

Mode switch

(acceleration

reference)

10

(min

−1

)/s

0

3000

0

Cn-0F

ERPMSW

Mode switch

(error pulse)

Reference

unit

0

10000

10

Cn-10

JOGSPD

Jog speed

min

−1

0

Maximum

speed

500

Cn-1E

OVRLV

Overflow

256

reference

unit

1

32767

1024

Cn-28

NFBCC

Speed loop

compensation

constant

---

0

100

0

Cn-29

AXISNO

Axis address

---

0

14

0

Cn-2A

INS1

Input signal

selection 1

---

0

3

0

See note 1

Cn-2B

INS2

Input signal

selection 2

---

0

3

2

See note 1

Cn-2C

OUTS2

Output signal

selection 2

---

0

4

3

See note 1

: Parameters that must always be set before turning ON power to the Servomotor.

Note

1) After changing the setting, always turn OFF the power, and then turn ON again to vali-

date the new settings.

2) Automatically set by autotuning function.

3) The following restriction applies to electronic gear ratio (Cn-24 and Cn-25):

0.01 ≦

B(Cn-24)
A(Cn-25) ≦

100

4) The soft-start function is valid during the jog operation or when the contact input speed

control mode is selected. The function is invalid during pulse command operations.