— 2-39 —

Some parameters for speed/torque control and position control have different meanings.
Refer to the list of parameters for each type.

For details of how to set parameters, refer to 3.1.5 Operation in Parameter Setting Mode.

2.3.2 Jog Speed

Use the following parameter to set or modify a motor speed when operating the Σ-Series Ser-

vo from a Digital Operator.

Cn-10

JOGSPD

Jog Speed

Unit:

min

−1

Setting

Range: 0

to

Maximum

Speed

Factory

Setting:

500