1.3Connection and Wiring

— 1-13 —

Molded-case circuit

breaker (MCCB)

Used to protect

power supply line.

Shuts the circuit

OFF when

overcurrent is

detected.

Noise filter

Used to eliminate external

noise from power supply line.

Power supply:

Single-phase

200 or 100 VAC

Molded-case
circuit breaker

Noise

filter

Magnetic contactor

Turns the Servo

ON or OFF.

Use a surge

suppressor for

the magnetic

contactor.

Model:

HI-Series

Magnetic

contactor

AC/DC power supply

Supplies Servopack

with 24 VDC.

AC/DC

power

supply

Power supply

ground line

Digital Operator

Allows the user to

set parameters or

operation references

and display

operation status or

alarm status.

Personal computers

can also be used.

Personal computer

Connecting cable: JZSP-CFS01 to 03

Encoder cable

Motor cable

JUSP-OP02A-3

Host

Controller

Connect the SGDP SERVOPACK to a

Yaskawa host controller.

MP910, MP920,
MP930, and MP−SG1 with a Motion Module

1