4.6.7 Noise Filter

— 4-62 —

4.6.7 Noise Filter

Install the following noise filter to prevent external noise from the power lines.

Servopack Capacity

Noise Filter Type

10 W, 20 W, 30 W

LF-205A

• LF-205A (Single-phase 200 VAC Class, 5 A)

IN Rating Plate

(1.57)

(1.18) (0.94)

(2.48)

(2.83)

(3.19)

(0.53)

(0.53)

(6-φ0.14)

(0.59)

(1.30)

4.6.8 Magnetic Contactor

The magnetic contactor is used to turn the servo power supply ON and OFF. Always attach a
surge suppressor to the magnetic contactor before using.

Use one 20-A magnetic contactor of the type shown below for a single Σ Series, regardless of

capacity. For multiple servo systems, select the magnetic contactor according to the total ca-
pacity.

Type: HI-11J (20 A)