7 noise filter, 8 magnetic contactor – Yaskawa Sigma Mini User Manual
Page 212
Advertising
SERVO SELECTION AND DATA SHEETS
4.6.7 Noise Filter
— 4-62 —
4.6.7 Noise Filter
Install the following noise filter to prevent external noise from the power lines.
Servopack Capacity
Noise Filter Type
10 W, 20 W, 30 W
LF-205A
• LF-205A (Single-phase 200 VAC Class, 5 A)
IN Rating Plate
(1.57)
(1.18) (0.94)
(2.48)
(2.83)
(3.19)
(0.53)
(0.53)
(6-φ0.14)
(0.59)
(1.30)
4.6.8 Magnetic Contactor
The magnetic contactor is used to turn the servo power supply ON and OFF. Always attach a
surge suppressor to the magnetic contactor before using.
Use one 20-A magnetic contactor of the type shown below for a single Σ Series, regardless of
capacity. For multiple servo systems, select the magnetic contactor according to the total ca-
pacity.
Type: HI-11J (20 A)
4
Advertising