5 operation in parameter setting mode – Yaskawa Sigma Mini User Manual

Page 131

Advertising
background image

3.1Basic Operations

— 3-7 —

3.1.5 Operation in Parameter Setting Mode

Parameters are used to select and adjust various functions. Two types of parameter are used
as follows:

Constant Settings (Cn-03 to Cn-2C)
Memory Switches (Cn-01, Cn-02)

The setting method is different for each type. The constant settings (Cn-03 to Cn-2C) allow
setting of a constant within a fixed range. The memory switches (Cn-01, Cn-02) allow the re-
quired functions to be selected. Refer to Appendix C List of Parameter Settings.

Changing the Constant Settings (Cn-03 to Cn-2C)

The constant settings (Cn-03 to Cn-2C) allow setting of a constant within a fixed range. Check
the permitted range of the constant in Appendix C List of Parameter Settings, before chang-
ing the data. The following example shows how to change user setting Cn-15 from 100 to 85.

1) Press

DSPL

SET

to select the parameter set-

ting mode.

2) Select the parameter number to set.

Press the

and

keys to select the

digit.

Press the

and

keys to change the

value.

3) Press

DATA

ENTER

to display the current data for

the parameter selected at step 2.

4) Set the required data.

Press the

and

keys to select the

digit.

Press the

and

keys to change the

value.

5) Press

DATA

ENTER

to store the data.

6) Press

DATA

ENTER

once more to display the pa-

rameter number again.

7) Repeat steps 2 to 6 as often as required.

3

Setting

Mode

The selected

digit flashes.

Parameter

Number

Data

The selected

digit flashes.

The stored

data flashes.

Parameter

Number

Data

Advertising