Input sg cn1-13, Input v-ref cn1-12 – Yaskawa Sigma Mini User Manual

Page 78

Advertising
background image

APPLICATIONS

2.2.7 Torque Control cont.

— 2-34 —

Input T-REF CN1-12

Torque Reference Input

For Speed/Torque

Control

Input SG CN1-13

Signal Ground for Torque

Reference Input

For Speed/Torque

Control

These signals are used when torque control is se-
lected (bits A and B of memory switch Cn-01).

Motor torque is controlled so that it is proportional
to the input voltage between T-REF and SG.

Standard Setting
Cn-13 = 30:

This setting means that 3 V is

equivalent to rated torque.

Examples:

+3 V input → Rated torque in forward direction

+9 V input → 300% of rated torque in forward direction

−0.3 V input → 10% of rated torque in reverse direction

Parameter Cn-13 can be used to change the voltage input range.

Example of Input Circuit:
See the figure on the right.

• For noise control, always use twisted-

pair cable.

• Example of Variable Resistor for Speed Setting:

Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.

Input V-REF CN1-12

Speed Reference Input

For Speed/Torque

Control

Input SG CN1-13

Signal Ground for Speed

Reference Input

For Speed/Torque

Control

These signals are used when speed control is se-
lected (bits A and B of memory switch Cn-01).

For normal speed control, always connect these
signal terminals.

Motor speed is controlled so that it is proportional
to the input voltage between V-REF and SG.

Standard Setting
Cn-03 = 500: This setting means that 6 V is equivalent to rated speed (3000 min

−1

).

Examples:

+6 V input → 3000 min

−1

in forward direction

+1 V input → 500 min

−1

in forward direction

−3 V input → 1500 min

−1

in reverse direction

2

Reference

torque

(%)

Standard

setting

Input voltage

(V)

Set the

slope in

Cn-13

(TCRFGN).

SG

T-REF

+12 V

Servopack

CN1-12

CN1-13

470 Ω

2 kΩ

1/2 W or more

Reference

speed (min

−1

)

Standard

setting

Input voltage

(V)

Set the slope

in Cn-03

(VREFGN).

Advertising